Abstract

Objective To evaluate and compare the stability of the open trayimpression coping within the set impression while attaching the lab analog when polyether (PE) heavy body and polyvinyl siloxane (PVS) putty impression materials were used and the implant platform was placed sub-gingivally at three different depths. Methods Two impression materials, PE and PVS, and custom-made plexiglass models with embedded single implants to simulate implant positioning depths of 0 mm, 2 mm, and 4 mm, sub-gingivally, were used in the study. Open tray impressions were made after attaching impression coping to theimplant embedded in themodel. Implant lab analog was attached to the impression coping in the set impression, and its stability was measured using a universal testing machine. Forty-two open tray impressions were madein six groups, with seven impressions in each group. Descriptive statistics such as mean and standard deviation were calculated. A comparison of the meanstability between the two impression materials at each depth was done using an independent t-test.Comparison of the mean stability between the three different subgingival implant depths in each material was done by one-way ANOVA with the Scheffe multiple comparison test (post-hoc analysis). The level of significance was set at p<0.05. Results The stability of the impression coping was measured as the force in Newtons required for the displacement of the analog attached to the impression coping embedded in the set impression. PEwith the embedded impression coping at a depth of 0 mm gave the highest mean stability value (4.37+/-0.41), and the least mean stability was offered by PVS with the embedded impression coping at 4 mm depth (1.88+/-0.37). When an independent t-test was done to compare the mean stability values of PE and PVS,there was a statistically significant difference at0 mm, 2 mm, and 4 mm. On doing one-way ANOVA to compare the mean stability between the different depth groups, there was a statistically significant difference between the three depth groups in PE and PVS. Scheffe multiple comparison tests (post-hoc analysis) revealed a statistically significant difference between 0 mm, 2 mm, and 4 mm subgingival depths of the impression coping placement in bothPE and PVS. Conclusion The accuracy of the master cast is an important determinant for the precise fit and long life of the final prosthesis. In the case of maxillary anterior implant placements where deep subgingival placement of the implant platform is needed for aesthetic and functional reasons, the impression material should be selected carefully to ensure the stability of the impression coping. Among the materials included in the present study, the PE impression material offered the maximum stability for impression coping compared to PVS.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.