Abstract

ObjectiveTo prepare the Simplified Therapeutic Intervention Scoring System (TISS-28) to measure nursing workload in Intensive Care Units in Guangdong Province of China. MethodsA non-experimental descriptive study was conducted in the intensive care units in the Province. TISS-28, TISS-76, Acute Physiology and Chronic Health Evaluation (APACHE II) were all measured. ResultsThere were significant positive correlations between TISS-28 and APACHE II (n=91, r=0.432, p<0.001), TISS-76 scores (n=83, r=0.764, p<0.001). A significant difference was found between the mean TISS-28 score in the first day of the intensive care stay and the last day (30.76±6.86 vs 24.67±5.48, p<0.001). A significant intra-class correlation was found between TISS-28 scores collected by the researcher and research associates (ICC=0.959, p<0.001). ConclusionThe reliability and validity of TISS-28 were shown in Chinese intensive care units. It is a practical tool for estimating the nursing workload and providing opportunities to compare the data between intensive care units in different facilities. The TISS-28 Chinese version is recommended to guide the allocation of nursing manpower in Chinese intensive care units.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.