Abstract
18F-labelled somatostatin receptor (SSTR) analogs offer several advantages over 68Ga in terms of yield, cost, spatial resolution and detection rate. This study presents an interim analysis of a prospective trial designed to assess the safety, biodistribution and dosimetry of [18F]AlF-NOTA-LM3, and compare its diagnostic efficacy and clinical management outcomes with [68Ga]Ga-DOTATATE or [68Ga]Ga-NODAGA-LM3 in patients with well-differentiated NETs. Twenty-one patients with histologically confirmed well-differentiated neuroendocrine tumors (G1 and G2) were prospectively recruited. The first eight patients underwent serial PET scans at 5, 15, 30, 45, 60, and 120min after [18F]AlF-NOTA-LM3 injection to assess biodistribution and dosimetry. The remaining patients underwent whole-body PET/CT scans. [18F]AlF-NOTA-LM3 and [68Ga]Ga-DOTATATE PET/CT were done within a week, with a minimum 24-hour interval between the two scans. Focal uptake above the surrounding background activity and could not be explained by physiologic uptake was considered lesions of NETs. Lesion number, tumor uptake, and tumor-to-background ratio (TBR) were compared. In patients with discrepant findings, the size of the smallest lesions (measured on coregistered CT) detected on [68Ga]Ga-DOTATATE and [18F]AlF-NOTA-LM3 was compared. [18F]AlF-NOTA-LM3 was safe and well-tolerated. Physiological uptake of [18F]AlF-NOTA-LM3 was significantly lower than that of [68Ga]Ga-DOTATATE in abdominal organs and bone marrow, but higher in blood pool and lung. The mean effective dose was 0.024 ± 0.014 mSv/MBq. [18F]AlF-NOTA-LM3 detected significantly more liver lesions (457 vs. 291, P = 0.006) and lymph node lesions (30 vs. 22, P = 0.011) compared to [68Ga]Ga-DOTATATE. The tumor uptake was comparable, but TBR was significantly higher with [18F]AlF-NOTA-LM3 for lesions from all sites except for the duodenum. The size of the minimum liver lesions (0.54 ± 0.15 vs. 1.01 ± 0.49, P<0.001) and lymph node lesions (0.50 ± 0.19 vs. 1.26 ± 0.86, P = 0.024) detected on [18F]ALF-NOTA-LM3 were significantly smaller than those detected on [68Ga]Ga-DOTATATE. [18F]AlF-NOTA-LM3 shows favorable biodistribution, higher spatial resolution and superior performance than [68Ga]Ga-DOTATATE in detecting liver and lymph node metastases, with higher TBR. Notably, it is the first SSTR analog to show superiority in detecting lymph node lesions when compared to [68Ga]Ga-DOTATATE. ClinicalTrials.gov identifier NCT06056362.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: European journal of nuclear medicine and molecular imaging
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.