Abstract

The purpose of this study was to measure mass loss and surface roughness changes of different brands of flowable resin composites after a simulated toothbrushing test. The null hypotheses were that there would be no differences in mass loss and no significant changes in surface roughness after this test and that there would be no correlation between the two variables. The tested materials were Aeliteflo (Bisco), Flow-It (Pentron), Flow-It LF (Pentron), Natural Flow (DFL) and Wave (SDI). Z100 (3M/ESPE) microhybrid and Silux Plus (3M/ESPE) microfilled resin composites were used as control materials. Twelve specimens (5 mm in diameter, 3 mm thick) of each material were prepared according to manufacturers' instructions. Toothbrushing abrasion was performed on all specimens from each of the materials using a simulator. The percentage mass loss and surface roughness were assessed before and after 100,000 brushstrokes, using a Sartorius analytical balance of 0.0001 g accuracy and a Hommel Tester T1000, respectively. The measurements of both properties were statistically compared by paired t-test and Tukey's test (p < 0.05). All materials presented a statistically significant mass loss comparing initial and final values, with the exception of Flow-It LF. However, no difference was revealed when comparing the mass loss of the different tested materials. All materials became rougher and Wave presented statistically higher roughness compared to the other resin composites. Flowable resin composites did not seem to be superior to the control groups, and they can be expected to wear by mass loss and to have an increased roughness of surface after toothbrushing action. The anticipated null hypotheses were partially accepted.

Highlights

  • Flowable resin composite is a category of low viscosity resin composites

  • The aim of this study was to determine the mass loss and surface roughness of five flowable, one microhybrid and one microfilled resin composites when subjected to a laboratory toothbrushing test

  • No significant differences in mass loss were observed among all tested resin composites (p = 0.43)

Read more

Summary

Introduction

Flowable resin composite is a category of low viscosity resin composites This formulation results in a material of low elastic modulus[3,21]. Due to this characteristic, it is recommended for clinical situations where oral forces need to be relieved, contributing to an even distribution of resultants[3]. It is recommended for clinical situations where oral forces need to be relieved, contributing to an even distribution of resultants[3] It can be applicable as liners or to restore Class V preparations. Depending on the degree of wear, a restoration can fail due to two main reasons: submargination[19] or changes in surface roughness[12]

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call