Two-tiered serologic testing for Lyme disease is usually performed using an enzyme-linked immunosorbent assay (ELISA) as the first-tier test. The Quidel Sofia 2 Lyme test is a relatively new lateral flow method to provide more rapid turnaround time. We evaluated its performance in comparison to an established ELISA method. The test can be performed on demand rather than batching assays in a central laboratory. We compared the Sofia 2 assay to the Zeus VlsE1/pepC10 IgG/IgM test in a standard two-tiered testing algorithm. Comparison of the Sofia 2 to the Zeus VlsE1/pepC10 IgG/IgM showed an overall agreement of 89.9% (κ statistic of 0.750, indicating "substantial agreement"). When the tests were followed by immunoblot in a two-tier algorithm, the agreement was 98.9% (κ statistic of 0.973, indicating "almost perfect" agreement). The Sofia 2 Lyme test performs well when compared with the Zeus VlsE1/pepC10 IgG/IgM in a two-tiered testing algorithm.