Abstract

This article is available from http://www.labmedonline.org 2012, Laboratory Medicine Online This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Background: Hemoglobin (Hb)-A1c is routinely used for the management of diabetes. In 2010, HbA1c was included into the diagnostic criteria for diabetes by the American Diabetes Association. A newly developed HbA1c analyzer, ARKRAY ADAMS HA-8180 (ARKRAY KDK, Japan) was introduced. In this study, we evaluated the analytical performance of ARKRAY ADAMS HA-8180 HbA1c analyzer and compared it with the previously used Variant II Turbo (Bio-Rad Laboratories, USA), which is a National Glycohemoglobin Standardization Program (NGSP) certified analyzer. Methods: According to Clinical Laboratory and Standards Institute (CLSI) evaluation protocol (EP) 5-A, Lyphochek Diabetes Controls (Bio-Rad Laboratories, USA) are used for precision. Two (low and high) levels of quality control materials were analyzed twice a day for 20 days, after which the mean, total standard deviation (SD) and total coefficient of variation (CV), including the between-run CV and between-day CV were calculated. ARKRAY ADAMS HA-8180 HbA1c analyzer and Variant II Turbo were compared with 150 samples according to CLSI EP9-A2. In addition, the linearity and carry over rate were evaluated. Results: Between-run CVs for low and high level quality control materials were 0.0% and 0.3%, respectively, whereas between-day CVs for low and high level quality control materials were 0.3% and 0.2%, respectively. In the linearity test, the coefficient of determination (R) was 0.99 (range, 3.1-19.3%). Thus, a good correlation was observed between ARKRAY ADAMS HA-8180 HbA1c analyzer and Variant II Turbo (R=0.994). The carry over rate was 0.0%. Conclusions: The ARKRAY ADAMS HA-8180 HbA1c analyzer showed excellent precision, linearity, and carryover rate. It also showed excellent correlation with the NGSP certified Variant II Turbo. In conclusion, the ARKRAY ADAMS HA-8180 HbA1c analyzer is a reliable high-performance liquid chromatography (HPLC) analyzer for HbA1c analysis and could be very useful for the diagnosis, treatment, monitoring, and risk assessment of diabetes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call