Abstract
The present work shows the evaluation of the flux and absorbed dose rate of neutrons in a 241AmBe Irradiator at IPEN facilities using the MCNP-4C transport code. The geometry of the 241AmBe source as well as the Irradiator design, constituted of 2 neutrons sources, were modeled. In addition, four and eight sources of 241AmBe were also considered for checking the viability to increase the Irradiator performance. The results show an increase for both flux and absorbed dose rate, mainly for the fast configuration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.