Abstract
Abstract Background It has been reported that low voltage areas and conduction abnormalities detected by electrophysiology catheters in the left atrium (LA) represent regional degeneration and fibrosis of the atrium and are related to a poor atrial fibrillation (AF) ablation outcome. Assessment of the local atrial function is clinically useful because atrial degeneration does not occur uniformly throughout the atrium. Though evaluating the global atrial function using speckle tracking imaging (STI) by transthoracic echocardiography (TTE) has been attempted, TTE does not have a sufficient image quality to assess local atrial STI. Purpose To evaluate the local atrial function by STI using intracardiac echocardiography (ICE) and to elucidate the characteristics of the STI in normal and abnormal voltage regions in the LA. Methods We included 9 patients undergoing AF ablation with written informed consent for this prospective observational study. After pulmonary vein isolation, we performed voltage mapping of the LA in sinus rhythm using a CARTO system (Biosense). Abnormal regions and normal regions were defined as those with low voltage areas (<0.5 mV) and those with normal voltages, respectively. Echo images were recorded by an ACUSON SC2000 (Siemens) and SOUNDSTAR catheter (Biosense). We inserted the SOUNDSTAR catheter into the LA to obtain clear images, recorded the STI of the anterior and inferior wall, and performed an offline analysis of the atrial strain with an eSie VVI work station (Siemens) and the LA voltage data with CARTO system at each site simultaneously (left figure). We compared the strain during the atrial contraction phase (Sct) between the normal and abnormal regions. Results Among the study population, 5 patients had low voltage areas in the LA. We evaluated the STI at 26 normal regions and 44 abnormal regions. The typical regional speckle tracking waveform in the normal region was similar to a jugular vein pressure waveform (right figure). There was a difference in the amplitude of the Sct between the groups; it was significantly smaller in the abnormal regions (normal and abnormal regions, 9.8±5.0% and 5.6±3.8%, p=0.0001). The duration of the Sct was significantly more prolonged in the abnormal regions than normal regions (98.8±26.3ms and 118.2±33.9ms, p=0.015). Conclusions This pilot study demonstrated that the local atrial function was evaluable by STI using ICE and that the regional strain tracking waveform during the atrial contraction phase in abnormal voltage regions was smaller and more prolonged than that in normal regions. An evaluation of the regional STI with an ICE may be useful to detect regional abnormalities of the atrium. Representative case Funding Acknowledgement Type of funding source: None
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.