Abstract

Flow-induced vibrations (FIV) continue to affect the operations of nuclear power plant components such as heat exchanger tube bundles. The negative effect of FIV is in the form of tube fatigue, cracking, and fretting wear at the supports. Fretting wear at the supports is the result of tube/support impact and friction. Fluidelastic and turbulence forces are the two main excitation mechanisms that feed energy into the system causing these violent vibrations. To minimize this effect all support clearances must be kept at a very small value. This paper investigates the consequences of losing the effectiveness of a particular support as a result of corrosion or excessive fretting wear. A full U-bend tube subjected to both fluidelastic and turbulence forces is utilized in this work. The performance of countermeasures such as the installation of additional flat bars in the U-bend region is thoroughly investigated. The investigation utilized both deterministic and probabilistic techniques.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.