Abstract
It has been suggested that hearing-impaired listeners with a good working memory (WM) should be fitted with a compression system using short time constants (i.e., fast-acting compression [FAC]), whereas those with a poorer WM should be fitted with a longer time constant (i.e., slow-acting compression [SAC]). However, commercial hearing aids (HAs) seldom use a fixed speed of compression. The performance of a variable speed compression (VSC) system relative to a fixed speed compressor (FAC and SAC) on measures of speech intelligibility, recall, and subjective report of listening effort and tolerable time was evaluated. The potential interaction with the listeners' WM capacity (WMC) was also examined. A double-blinded, repeated measures design. Seventeen HA wearers (16 with greater than one year HA experience) with a bilaterally symmetrical, mild to moderately severe sensorineural hearing loss participated in the study. Participants wore the study HAs at three compression speeds (FAC, SAC, and VSC). Each listener was evaluated on the Office of Research in Clinical Amplification-nonsense syllable test (NST) at 50 dB SPL (signal-to-noise ratio [SNR] = +15 dB), 65 dB SPL (SNR = +5 dB), 80 dB SPL (SNR = 0 dB), and a split (80 dB SPL-50 dB SPL) condition. Listeners were also evaluated on a Repeat Recall Test (RRT), where they had to repeat six short sentences (both high- and low-context sentences) after each was presented. Listeners recalled target words in all six sentences after they were presented. They also rated their listening effort and the amount of time they would tolerate listening under the specific condition. RRT sentences were presented at 75 dB SPL in quiet, as well as SNR = 0, 5, 10, and 15 dB. A Reading Span Test (RST) was also administered to assess listeners' WMC. Analysis of variance using RST scores as a covariate was used to examine differences in listener performance among compressor speeds. Listener performance on the NST was similar among all three compression speeds at 50, 65, and 80 dB SPL. Performance with FAC was significantly better than SAC for the split condition; however, performance did not differ between FAC and VSC or between SAC and VSC. Performance on the NST was not affected by listeners' RST scores. On the RRT, there was no effect of compressor speed on measures of repeat, recall, listening effort, and tolerable time. However, VSC resulted in significantly lower (better) speech reception threshold at the 85% correct recognition criterion (SRT85) than FAC and SAC. Listener RST scores significantly affected recall performance on the RRT but did not affect SRT85, repeat, listening effort, or tolerable time. These results suggest that the VSC, FAC, and SAC yield similar performance in most but not all test conditions. FAC outperforms SAC, where the stimulus levels change abruptly (i.e., split condition). The VSC yields a lower SRT85 than a fixed compression speed at a moderately high level with a favorable SNR. There is no interaction between compression speed and the participants' WMC.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.