This paper presents a simplified analysis to determine the variables that affect the empirical correlation factor used in the lead peroxide method. The rate of sulfation has been determined from two different models. In the first model, the mass transfer rate is calculated from the gas phase resistance alone whereas in the second model, the diffusion resistance in the gel phase is assumed to be the rate limiting step. Although the gas phase and the gel phase resistances may be both important in the actual case, it has been found that the correlation factor based on the first model is adequate to describe general experimental observations. Reasonable agreement has been obtained between the measured and the calculated va|ue of the correlation factor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.