Abstract

Background and study aimsThe single-operator cholangiopancreatoscopy (SOCP) with the SpyGlass™ system is a endoscopy technique whose use has grown exponentially in recent years. The aims of this study were to evaluate the efficacy and safety of SOCP with SpyGlass™ and determine the factors related to the onset of adverse events (AEs). Patients and methodsRetrospective study at a single tertiary institution with inclusion of all consecutive patients undergoing SOCP with SpyGlass™ from February-2009 to December-2021. No exclusion criteria were considered. A descriptive statistical analysis was performed. The factors associated with the existence of AE were analyzed using Chi-square and Student's t-test. ResultsA total of 95 cases were included. The most common indications were biliary strictures (BS) evaluation (66.3%) or treatment of difficult common bile duct stones (27.4%). Technical and clinical success was attained in 98.9%. Single-session stone clearance was obtained in 84%. The AE rate was 7.4%. To detect malignancy in BS, optical diagnosis presents a sensitivity and specificity of 100% and 91.2%, respectively; while histology results were 36.4% and 100% respectively. A previous endoscopic sphincterotomy was associated with a lower rate of AEs (2.4% vs 41.7%; p<0.001). ConclusionsSOCP with SpyGlass™ is a safe and effective technique to diagnose and treat pancreatobiliary pathology. The presence of sphincterotomy performed prior to the procedure could improve the technique's safety.