Abstract

We describe an evaluation of the effect of the magnetic field on the PET spatial resolution and contrast recovery for long range positron emitters on Siemens' Biograph-mMR (mMR) and Biograph-40 (B40) multi-modality PET scanners as well as using electron transport simulations (EGS). A <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">68</sup> Ga line source surrounded by water and a <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">68</sup> Ga contrast phantom with various sphere sizes were scanned on the mMR (magnetic field strength: 3T) and B40 (magnetic field strength: OT). The line source was aligned with the magnetic field and positioned near the center of the field of view. The acquired data were reconstructed with FBP. The EGS simulations were performed from OT to 11 T for both <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">68</sup> Ga and <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">76</sup> Br (a longer range positron emitter) for the contrast phantom and line source. The FWHM and FWTM of the line source as well as the sphere contrast of the contrast phantom were measured for the experimental and simulated images for the plane perpendicular to the magnetic field. The resolution and contrast obtained from the plane parallel to the magnetic field were also investigated using phantom experiments and EGS. Slight improvements in spatial resolution and contrast were observed on the plane perpendicular to the magnetic field from phantom experiments and simulations. The degree of the improvement is proportional to the positron range of the nuclides as well as the strength of the magnetic field, and it saturates at ~7T for all nuclides used in this study. For the plane parallel to the magnetic field, slightly worse resolution and better contrast were observed. In addition, a directionally dependent resolution modeling which accounts for the effect of the magnetic field in iterative PET reconstruction was observed to improve the resolution recovery in the plane parallel to the magnetic field.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.