Abstract

Radium, which is naturally present in many building materials, decays to the radioactive gas radon, which is exhaled from the surface of concrete block and is a major source of human exposure to radioactivity. In this study, an experimental evaluation of radon exhalation was conducted on a concrete block covered with mortar and acrylic render. Factors such as sand aggregates content and water content of the mortar cover layer, the thickness of the double cover layer were considered. Results showed that the radon exhalation rate was increased with an increase of sand content in mortar cover layer, and the radon exhalation rate was reduced with an increase of the thickness and water content. Besides, indoor radon concentration and effective dose estimation involving concrete block with cover layer were evaluated. The calculated indoor radon concentration was reduced from 234.9 to 201.1 Bq m−3 as the thickness of the cover layer was increased from 15 to 35 mm, and the effective dose was reduced by 0.61 mSv y−1. Therefore, the addition of a cover layer on the indoor walls, floors and ceilings could reduce the indoor radon concentration and the radon dose on exposure to occupants.