When boiler assemblies are operated on coal, dust fuel, the main mason for breakdowns of the tubular air heaters (TAH) is the abrasive wear on the input surface of the tubes by the particles of ash contained in the effluent gas and also the corrosive wear on the tubes as a result of the condensation of sulfur-containing components of the fuel. With the aim of avoiding the corrosion of the tubes, the All-Union Institute has developed a technology for protecting their inner surfaces with the enamel coating 13-111.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.