Abstract

Objective To compare the time savings and accuracy rates of a manual dispensing system with the Drug-O-Matic (DOM), an automated tablet and capsule counter. Design In part one, phase A of this two-part study, a time trial measured the time of the prescription-filling process using the manual method. In part one, phase B, a time trial measured the time of that process using the DOM system. Part two of the study measured the accuracy of the DOM. Results The DOM requires 9 hours 42 minutes less per day than does the manual system. However, its accuracy causes some concern because we found a 14 percent discrepancy rate in terms of over- and underfills. Conclusions Our initial experience with the DOM suggests significant time-savings potential compared with the manual method of prescription filling, and our institutional goal is to translate the time saved into other activities that will allow us to function as a free-standing pharmacy. A concern is the DOM's 14 percent discrepancy rate. Further studies are needed to confirm or challenge our initial findings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.