Abstract
The dose rate distributions in the 29,000-Ci 60Co irradiation facility in National Tsing Hua University were investigated by measurements and calculations. The dose rate measurements were performed using radiochromic dye films and an Exradin A2 ion chamber mounted on a PC-controlled motorised vertical translation stage. The calculations were made by using the three-dimensional point kernel code QAD-CGGP with detailed source composition and geometry modelling. The scattered gamma rays from the walls of the irradiation cell were also evaluated by using the Monte Carlo code MCNP.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.