Abstract

BackgroundThe aim of this study was to establish a set of assessment methods suitable for evaluating the complex indoor environment of hospital wards and to ascertain the composition of bacteria and microbial ecology of hospital wards.MethodsColony-forming units (CFUs), PM2.5 detection, real-time PCR, and adenosine triphosphate (ATP) bioluminescence assay were employed to evaluate the complexity of indoor air in 18 wards of nine departments in a hospital and two student dormitories in a university. Subsequently, the microbial samples were quantified and identified using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS).ResultsAlthough the studied indices were relatively independent, the PM2.5 content was correlated with bacterial CFUs determined by passive sedimentation method, bacterial and fungal counts measured by real-time PCR, and ATP bioluminescence assay. The composition of microorganisms in the air of hospital wards differed from that in the air of student dormitories. The dominant genera in hospital wards were Staphylococcus (39.4%), Micrococcus (21.9%), Corynebacterium (11.7%), Kocuria (4.4%), Bacillus (2.9%), Streptococcus (1.6%), Moraxella (1.6%), and Enterococcus (1.3%), and the microbial ecology differed between Respiration Dept. III and other hospital departments. Additionally, 11.1 and 27.3% of bacteria in hospital wards and student dormitories were not identified, respectively.ConclusionsAssessment of environmental quality of hospital wards should be based on comprehensive analysis with multiple indicators. There may be imbalances in the microbial diversity in the hospital wards, therefore, monitoring of the environmental quality of hospitals is important in the prevention of nosocomial infections.

Highlights

  • The aim of this study was to establish a set of assessment methods suitable for evaluating the complex indoor environment of hospital wards and to ascertain the composition of bacteria and microbial ecology of hospital wards

  • The PM10 concentration in all the wards and dormitories examined in this study did not exceed the limit, and the highest PM10 content was noted in the GI Surgery Dept

  • Assessment of environmental quality of hospital wards should be based on comprehensive analysis with multiple indicators

Read more

Summary

Introduction

The aim of this study was to establish a set of assessment methods suitable for evaluating the complex indoor environment of hospital wards and to ascertain the composition of bacteria and microbial ecology of hospital wards. The air quality of hospitals may be an important risk factor affecting the health of patients, and assessment of hospital environment is significant. Some researches have been showed that environmental contamination may promote the infection and transmission of healthcare-associated pathogens, including methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus spp. A study conducted in the USA about hospital nurses confirmed that PM2.5 was related to the risk of all-cause mortality [26]. The traditionally applied methods, to assess microbial air contamination and cleanliness on surfaces in hospital are based on microbiological cultural technology, including active, passive and surfaces sampling [27]. Comprehensive indicators, including fine particles, total microorganisms (including dead microorganisms), culturable microorganisms, and number of living cells, are needed to analyze the complex hospital wards environment

Objectives
Methods
Results
Discussion
Conclusion