Abstract

IntroductionThe interest in quality management tools/methodologies is gradually increasing to ensure quality and accurate results in line with international standards in clinical laboratories. Six Sigma stands apart from other methodologies with its total quality management system approach. However, the lack of standardization in tolerance limits restricts the advantages for the process. Our study aimed both to evaluate the applicability of analytical quality goals with Roche Cobas c 702 analyser and to determine achievable goals specific to the analyser used.Materials and methodsThe study examined under two main headings as Sigmalaboratory and Sigmaanalyser. Sigmalaboratory was calculated using internal and external quality control data by using Roche Cobas c 702 analyser for 21 routine biochemistry parameters and, Sigmaanalyser calculation was based on the manufacturer data presented in the package inserts of the reagents used in our laboratory during the study. Sigma values were calculated with the six sigma formula.ResultsConsidering the total number of targets achieved, Sigmaanalyser performed best by meeting all CLIA goals, while Sigmalaboratory showed the lowest performance relative to biological variation (BV) desirable goals.ConclusionsThe balance between the applicability and analytical assurance of “goal-setting models” should be well established. Even if the package insert data provided by the manufacturer were used in our study, it was observed that almost a quarter of the evaluated analytes failed to achieve even “acceptable” level performance according to BV-based goals. Therefore, “state-of-the-art” goals for the Six Sigma methodology are considered to be more reasonable, achievable, and compatible with today’s technologies.

Highlights

  • The interest in quality management tools/methodologies is gradually increasing to ensure quality and accurate results in line with international standards in clinical laboratories

  • Even if the package insert data provided by the manufacturer were used in our study, it was observed that almost a quarter of the evaluated analytes failed to achieve even “acceptable” level performance according to biological variation (BV)-based goals

  • We aimed to evaluate the applicability of analytical quality goals with Roche Cobas c 702 analyser and to determine analytical goals depending on the analyser used

Read more

Summary

Introduction

The interest in quality management tools/methodologies is gradually increasing to ensure quality and accurate results in line with international standards in clinical laboratories. The interest in quality management tools/methodologies is gradually increasing to achieve quality and accurate results in line with international standards in the clinical laboratory. ©Copyright by Croatian Society of Medical Biochemistry and Laboratory Medicine

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call