Abstract

Microscopic detection of Plasmodium species has been the reference standard for the diagnosis of malaria for more than a century. However, maintaining a sufficient level of expertise in microscopic diagnosis can be challenging, particularly in non-endemic countries. The objective of this study was to compare a new rapid malaria diagnostic device (NOW ICT Malaria Test; Binax, Inc., Portland, ME) to polymerase chain reaction (PCR) and expert microscopy for the diagnosis of malaria in 256 febrile returned travelers. Compared with PCR, the NOW ICT test showed a sensitivity of 94% for the detection of P. falciparum malaria (96% for pure P. falciparum infection) and 84% for non-P. falciparum infections (87% for pure P. vivax infections and 62% for pure P. ovale and P. malariae infections), with an overall specificity of 99%. The Binax NOW ICT may represent a useful adjunct for the diagnosis of P. falciparum and P. vivax malaria in febrile returned travelers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call