Abstract

Nasopharyngeal swab specimen (NPS) molecular testing is considered the gold standard for SARS-CoV-2 detection. However, saliva is an attractive, noninvasive specimen alternative. The aim of the study was to evaluate the diagnostic accuracy of Advanta Dx SARS-CoV-2 RT-PCR saliva-based assay against paired NPS tested with either NeumoDxTM SARS-CoV-2 assay or Abbott Real Time SARS-CoV-2 assay as the reference method. We prospectively evaluated the method in two settings: a diagnostic outpatient and a healthcare worker screening convenience sample, collected in November–December 2020. SARS-CoV-2 was detected in 27.7% (61/220) of diagnostic samples and in 5% (10/200) of screening samples. Overall, saliva test in diagnostic samples had a sensitivity of 88.5% (77.8–95.3%) and specificity of 98.1% (94.6–99.6%); in screening samples, the sensitivity was 90% (55.5–99.7%) and specificity 100% (98.1–100%). Our data suggests that the Fluidigm Advanta Dx RT-PCR saliva-based assay may be a reliable diagnostic tool for COVID-19 diagnosis in symptomatic individuals and screening asymptomatic healthcare workers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.