Abstract
BackgroundEvaluation of the microcirculation in critically ill patients is usually done by means of indirect parameters. The aim of our study was to evaluate the functional state of the microcirculation by direct visualization of sublingual microcirculation using Sidestream Dark Field Imaging, to determine the correlation between these findings and other parameters that are commonly used in the clinical practice and to assess the applicability of the systematic use of this technique in critically ill children.MethodsA prospective observational study was carried out in a Pediatric Intensive Care Unit (PICU) of a tertiary referral hospital. All patients admitted to the PICU during a three-month period were included in the study after obtaining the informed consent from the patient. Systematic evaluation of sublingual microcirculation was done in these patients (Total Vessel Density, Proportion of Perfused Vessels, Perfused Vessel Density, De Backer Score, Microvascular Flow Index, Heterogeneity Index) within the first day of admission (T1) and between the second and third day of admission (T2). Other clinical, hemodynamic, and biochemical parameters were measured and registered simultaneously. When the evaluation of the microcirculation was not feasible, the reason was registered. Descriptive analysis of our findings are expressed as means, medians, standard deviations and interquartile ranges. Mann–Whitney-Wilcoxon and Fisher tests were used to compare variables between patients with and without evaluation of the microcirculation. Pearson Correlation Coefficient (ρ) was used to evaluate the correlation between microcirculatory parameters and other clinical parameters.ResultsOne hundred fine patients were included during the study period. Evaluation of the microcirculation was feasible in 18 patients (17.1%). 95.2% of them were intubated. The main reason for not evaluating microcirculation was the presence of respiratory difficulty or the absence of collaboration (95.1% on T1 and 68.9% on T2). Evaluated patients had a higher prevalence of intubation and ECMO at admission (72.2% vs. 14.9% and 16.6% vs. 1.1%, respectively), and longer median duration of mechanical ventilation (0 vs. 6.5 days), vasoactive drugs (0 vs. 3.5 days) and length of stay (3 vs. 16.5 days) than non-evaluated patients. There was a moderate correlation between microcirculatory parameters and systolic arterial pressure, central venous pressure, serum lactate and other biochemical parameters used for motoring critically ill children.ConclusionsSystematic evaluation of microcirculation in critically ill children is not feasible in the unstable critically ill patient, but it is feasible in stable critically ill children. Microcirculatory parameters show a moderate correlation with other parameters that are usually monitored in critically ill children.
Highlights
Evaluation of the microcirculation in critically ill patients is usually done by means of indirect parameters
Microcirculatory parameters show a moderate correlation with other parameters that are usually monitored in critically ill children
Some new techniques for direct visualization of the microvascular compartment have been developed in the last few years, such as sidestream dark field (SDF) microscopy [3] and orthogonal polarization spectral (OPS) imaging [4, 5]
Summary
Evaluation of the microcirculation in critically ill patients is usually done by means of indirect parameters. The aim of our study was to evaluate the functional state of the microcirculation by direct visualization of sublingual microcirculation using Sidestream Dark Field Imaging, to determine the correlation between these findings and other parameters that are commonly used in the clinical practice and to assess the applicability of the systematic use of this technique in critically ill children. Some studies show that direct visualization of the microcirculation has prognostic implications and can be useful for guiding further management of the critically ill patient [6,7,8,9,10,11,12,13] These techniques are not yet widely used in routine clinical practice
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.