Abstract
A simple, rapid, accurate, precise and robust HPLC method was developed for the simultaneous determination of fimasartan and amlodipine in tablet dosage form. Furthermore, stability of active ingredients was evaluated under normal and stress conditions. The isocratic elution was accomplished by Nucleosil C18 column (250 mm × 4.6 mm, 5 μm) at 40 °C. The mobile phase consisted of acetonitrile and 0.02 M monopotassium phosphate buffer (pH 2.2) in the ratio of 50:50 (v/v) was eluted at 1.0 ml/min. The eluent was monitored by the UV detector for fimasartan and amlodipine at 237 nm for 8 min, detection time. The validation of HPLC method was carried out in accordance with the ICH guidelines.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.