Abstract

Relationships of airborne dust concentrations measured by cyclone and elutriator size-selective presamplers are presented. Cyclone efficiency is assumed to fallow the Los Alamos criterion, and that of the elutriator the British Medical Research Council criterion. Cyclone-elutriator ratios are given for log-normally distributed aerosols with a count median diameter range of 0.1 to 11.0 microns and a mass median diameter range of 0.2 to 16 microns for geometric standard deviations of 1.1 to 3.0. For usual heterogeneous industrial dust clouds, the ratio is 0.81 ± 0.11. For these same dust clouds the cyclone passes from 2% to 75% of the total dust, and the elutriator from 4% to 81%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.