Abstract

This study presents a novel approach to assessing the setting time of concrete using the electro-mechanical impedance (EMI) sensing technique. The proposed method involves the continuous monitoring of EMI changes by embedding a piezoelectric (PZT) sensor directly in the concrete. A comparative analysis was conducted with the conventional penetration resistance test, which utilizes mortar samples extracted from the concrete. As a result of the experiment, the time deviation rate of the setting time was more than 10% in the penetration resistance test using the mortar sample extracted from the same concrete, whereas the time deviation rate of the setting time was up to 1.77% in the EMI sensing technique using the same concrete specimen. This highlights the effectiveness and potential of the EMI sensing technique for an improved evaluation of concrete setting time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.