Abstract

The feasibility of measuring residual stresses in Self-Pierce Riveted (SPR) joints by neutron diffraction was evaluated in this study. Despite the small dimensions involved, meaningful results were obtained. It was observed that residual stress in the rivet head was higher in the centre and lower at the edge. For the SPR joints examined, the maximum value of residual stress evaluated was 550MPa, compressive and occurred in the rivet leg. Stresses in material adjacent to the rivet wall and at a distance of three times the rivet radius from the rivet axis were not significant. The results are discussed with respect to the physical events involved during SPR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.