Abstract

<p>When assessing the structural behaviour of prestressed concrete bridges, understanding the level of prestressing is crucial. However, for existing structures, this is usually an unknown parameter and the literature only describes a few methods of experimentally determining the residual prestress forces. For this paper, a non-destructive testing approach has been evaluated based on testing of a multi-span continuous girder bridge. The method, consisting of in-situ measurements in combination with finite element (FE) simulations, revealed prestress levels in the range 25 % to 82 % of the reinforcement steel yield strength, depending on the section tested. A comparison with theoretically calculated residual prestress forces, taking into account friction and time- dependent losses, indicated values of the same order but with some inconsistencies.</p>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.