Abstract
Data are presented on several low dose rate sensitive bipolar linear circuits to evaluate a proposed hardness assurance method. The circuits include primarily operational amplifiers and voltage comparators with a variety of sensitive components and failure modes. The proposed method, presented in 1997, includes an option between a low dose rate test at 10 mrd(Si)/s and room temperature and a 100/spl deg/C elevated temperature irradiation test at a moderate dose rate. The results of this evaluation demonstrate that a 10 mrd(Si)is test is able (in ail but one case) to bound the worst case response within a factor of 2. For the moderate dose rate, 100/spl deg/C test the worst case response is within a factor of 3 for 8 of 11 circuits, and for some circuits overpredicts the low dose rate response. The irradiation bias used for these tests often represents a more degrading bias condition than would be encountered in a typical space system application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.