Abstract

In this paper, we report the results for pressures in a full-scale silo obtained from assays performed on a test station using a free-flowing product. Six different types of silo geometry (slenderness and hopper angle) were tested by filling the silo to the height of interest and observing a static phase (10 min) followed by complete discharge. Our results show that discharge flow is not influenced by silo slenderness. The lateral pressure ratio and values obtained for vertical stress in the stored material at the transition were higher than those given in the Eurocode 1, part 4. In addition, the maximum frictional pressures in the cylinder showed peaks that exceeded the standard, as did the maximum normal pressure in the cylinder with maximum slenderness and mass flow (hopper β = 15°).

Full Text
Published version (Free)