Abstract
Various experiments on the pressure drop of a two-phase flow boiling in a mini channel tube have been carried out. This study is aimed at characteristics of the pressure drop of a two-phase flow boiling using a refrigerant R290. The experiment uses a horizontal, stainless steel, 2-m-long mini-channel tube with a 3-mm inner diameter. The experiment has been carried out using various data with the vapor qualities ranging from 0.1 to 0.9, the mass fluxes ranging 50 kg/m2s to 180 kg/m2s, and the heat fluxes ranging from 5 kW/m2 to 20 kW/m2. Furthermore, several homogeneous and separated methods were used to predict the experimental data. Li and Hibiki’s correlation give the best overall deviation pressure drop value is the most accurate with its deviation amounting 19.47%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.