Abstract

The aim of this study was to describe visualisation rate and appearance of all pericardial sinuses and recesses and to evaluate whether there is a significant difference between visualisation of these sinuses and recesses on 2-, 4-, 16- and 64-slice multidetector computed tomography (MDCT). We retrospectively analysed 588 MDCT scans of the chest obtained with a protocol for pulmonary embolism. The visualisation rate of any pericardial recess was 85.2%. The rates on 2-, 4-, 16- and 64-slice MDCT were 74.7%, 90.6%, 90.3% and 88.7%, respectively. There was a statistically significant difference in visualisation rates of pericardial recesses between 2-slice MDCT and other MDCT systems (p<0.01). Age, and 4-, 16- and 64-slice MDCT versus 2-slice MDCT and the presence of pleural effusion appeared as significant predictors of the presence of any recess. Visualisation rates of pericardial recesses are higher with 4-, 16- and 64-slice MDCT than with 2-slice MDCT. Therefore, radiologists need to be familiar with the different appearances of pericardial recesses on MDCT to avoid misdiagnosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.