Abstract
To measure the complex nasal clearance we propose to perform our variation of the Andersen saccharin method as a saccharin liquid test (SLT). The application of 3 molar aqueous sodium saccharin solutions with a Wiretrol capillary on the concha nasalis inferior or media allows simple handling, exact dosage, minimal nasal irritation and an increase in reproducibility. Application of 1 microlitre is sufficient to carry out the test. In the present study 48 healthy volunteers without any nose disease or history of sinusitis showed a saccharin transport rate of 10.4 (SD 4.2) minutes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.