Abstract
The aim of this in vitro study was to examine the effect of Er,Cr:YSGG laser-assisted tooth bleaching treatment on the elution of monomers and surface roughness of a hybrid computer-aided design-computer-aided manufacturing (CAD-CAM) material, and to compare it with a resin composite for direct restorations. Forty specimens of a hybrid CAD-CAM material (Enamic) and forty of a conventional resin composite (Tetric) were fabricated and randomly divided into four groups (n=10). Half of the specimens of each material were stored in distilled water and the other half in artificial saliva for 7 days. At the end of this period, the storage medium was analyzed by high-performance liquid chromatography (HPLC), and the surface roughness parameters of the specimens were evaluated by optical imaging noncontact interferometric profilometry. Afterwards, half of the specimens of each tested material received a conventional in-office tooth bleaching treatment and the other half an Er,Cr:YSGG laser-assisted bleaching treatment, and then they were again incubated in distilled water and artificial saliva for an additional 7-day time period. At the end of this period, the effect of the bleaching treatments on elution of monomers and surface roughness of the tested materials was evaluated. Bisphenol A (BPA), urethane dimethacrylate (UDMA), triethylene glycol dimethacrylate (TEGDMA), and bisphenol A-glycidyl dimethacrylate (BisGMA) were eluted from the conventional resin composite into both the solutions tested. Only TEGDMA was eluted from the hybrid CAD-CAM material. However, no statistically significant differences were found among the surface roughness parameters of both materials. Both the conventional and Er,Cr:YSGG laser-assisted tooth bleaching treatments affected the monomer elution from the composite resin. However, there were no statistically significant differences (p<0.05) between the treatments. According to the results of this study, tooth bleaching with Er,Cr:YSGG laser or conventional technique is safe, even if the bleaching agent comes in contact with hybrid CAD-CAM restorations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.