Abstract
The pilot-scale Taylor–Couette UV unit was tested at turbulent vortices (TV), transitional (TRA) and Couette–Poisuille (CP) flow conditions to treat apple cider (pH 3.65, α=17.41cm−1), carrot juice (pH 6.31, α=52.69cm−1) and soy milk (pH 7.04, α=162.01cm−1) for inactivation of Escherichia coli ATCC 8739. The germicidal effectiveness of Taylor–Couette unit was dependent on Taylor and Reynolds numbers and flow regimes formed in the annulus. From all studied flow regimes the CP flow resulted in the lowest microbial inactivation. For instance at the flow rate of 1500ml/min and rotation of 0rpm the UV decimal reduction dose in apple cider was of 13.15±0.45mJ/cm2. On the contrary the superior E. coli inactivation was achieved at the TV flow (1500mL/min, 200rpm,), characterised by the least UV decimal reduction dose of 4.57±0.35mJ/cm2. Obtained results indicate that Taylor–Couette UV unit provided efficient mixing conditions capable of overcoming the low penetration of UV photons in opaque liquids.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.