Abstract

BackgroundMicrobubbles (MBs) can serve as an ultrasound contrast agent, and has the potential for magnetic resonance imaging (MRI). Due to the relatively low effect of MBs on MRI, it is necessary to develop new MBs that are more suitable for MRI. In this study, we evaluate the properties of SonoVue® and custom-made Fe3O4-nanoparticle-embedded microbubbles (Fe3O4-MBs) in terms of contrast agents for ultrsonography (US) and MRI.Methodology/Principal FindingsA total of 20 HepG2 subcutaneous-tumor-bearing nude mice were randomly assigned to 2 groups (i.e., n = 10 mice each group), one for US test and the other for MRI test. Within each group, two tests were performed for each mouse. The contrast agent for the first test is SonoVue®, and the second is Fe3O4-MBs. US was performed using a TechnosMPX US system (Esaote, Italy) with a contrast-tuned imaging (CnTI™) mode. MRI was performed using a 7.0T Micro-MRI (PharmaScan, Bruker Biospin GmbH, Germany) with an EPI-T2* sequence. The data of signal-to-noise ratio (SNR) from the region-of-interest of each US and MR image was calculated by ImageJ (National Institute of Health, USA). In group 1, enhancement of SonoVue® was significantly higher than Fe3O4-MBs on US (P<0.001). In group 2, negative enhancement of Fe3O4-MBs was significantly higher than SonoVue® on MRI (P<0.001). The time to peak showed no significant differences between US and MRI, both of which used the same MBs (P>0.05). The SNR analysis of the enhancement process reveals a strong negative correlation in both cases (i.e., SonoVue® r = −0.733, Fe3O4-MBs r = −0.903, with P<0.05).ConclusionsIt might be important to change the Fe3O4-MBs' shell structure and/or the imagining strategy of US to improve the imaging quality of Fe3O4-MBs on US. As an intriguing prospect that can be detected by US and MRI, MBs are worthy of further study.

Highlights

  • As an intriguing prospect that can be detected by US and magnetic resonance imaging (MRI), MBs are worthy of further study

  • Angiogenesis is a determinant of tumor growth, invasion, and metastasis [1]

  • When the imaging strategy changed from contrast-tuned imaging (CnTITM) to the Flash mode, the SonoVueH microbubbles broke and the enhanced signal generated by the microbubbles changed to anecho

Read more

Summary

Introduction

Angiogenesis is a determinant of tumor growth, invasion, and metastasis [1]. To detect new tumor microvessels, modern medical imaging modalities are widely used. Ultrasound contrast agents (UCAs) are microbubbles (MBs), which are often 1–7 mm in diameter and are used primarily as blood-pool markers [2]. Recent theoretical and phantom studies had further demonstrated this [5,6,7,8,9]. The principle behind their use in MRI was the gas-liquid interface or the pressureinduced microbubble size changing, which induced large local magnetic susceptibility differences. Microbubbles (MBs) can serve as an ultrasound contrast agent, and has the potential for magnetic resonance imaging (MRI). We evaluate the properties of SonoVueH and custom-made Fe3O4-nanoparticle-embedded microbubbles (Fe3O4-MBs) in terms of contrast agents for ultrsonography (US) and MRI

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call