Abstract

Ambient dose equivalent H*(10) is an operational quantity recommended by the IAEA to establish dose constraints in area monitoring for external radiation. The direct measurement of H*(10) is not common due to the complexity in the calibration procedures of radiation monitors involving the use of expanded and aligned radiation fields. Therefore, conversion coefficients are used to assess H*(10) from the physical quantity air-kerma. Conversion coefficients published by international commissions, ICRU and ICRP, present a correlation with the radiation beam quality. However, Brazilian regulation establishes 1.14 Sv Gy−1 as unique conversion coefficient to convert air-kerma into H*(10), disregarding its beam quality dependence. The present study computed mean conversion coefficients from secondary and transmitted x-ray beams in order to improve the current assessment of H*(10). The weighting of conversion coefficients corresponding to monoenergetic beams with the spectrum energy distribution in terms of air-kerma was used to compute the mean conversion coefficients. In order to represent dedicated chest radiographic facilities, an anthropomorphic phantom was used as scatter object of the primary beam. Secondary x-ray spectra were measured in the diagnostic energy range at scattering angles of 30°, 60°, 90° 120° and 150° degrees. Barite mortar plates were used as attenuator of the secondary beam to produce the corresponding transmitted x-ray spectra. Results show that the mean conversion coefficients are about 43% higher than the recommended value accepted by Brazilian regulation. For secondary radiation measured at 100 kV the mean coefficient should be 1.46 Sv Gy−1, which represent the higher value in the mean coefficient set corresponding to secondary beams. Moreover, for transmitted x-ray beams at 100 kV, the recommended mean conversion coefficient is 1.65 Sv Gy−1 for all barite mortar plate thickness and all scattering angles. An example of application shows the discrepancy in the evaluation of secondary shielding barriers in a controlled area when the shielding goals is evaluated. The conclusion based on these results is that a unique coefficient may not be adequate for deriving the H*(10).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call