Abstract

This in vitro study aimed to assess and contrast the marginal and internal adaptation of all-ceramic prefabricated veneers manufactured via the FirstFit guided tooth preparation system against all-ceramic veneers produced using the chairside Computer-Aided Design/Computer Aided Manufacture (CAD/CAM) system following identical guided preparation protocols. Two main groups were included, with 16 lithium disilicate veneers per group. Four typodonts were used for the test (FirstFit) and control CAD/CAM groups. Intraoral scans created master casts and preparation guides. Guides performed preparations on typodont teeth (two central incisors and two lateral incisors). Prepared teeth were scanned (CEREC Omnicam) to design and mill CAD/CAM veneers. Marginal gap thickness and cement space thickness were measured using light microscopy at four locations: marginal, cervical internal, middle internal, and incisal internal. No significant difference existed between groups for marginal adaptation (p = 0.058) or incisal internal adaptation (p = 0.076). The control group had significantly lower values for middle internal adaptation (p = 0.023) and cervical internal adaptation (p = 0.019). Guided preparation evaluation showed no significant differences in marginal or incisal internal adaptation. The CAD/CAM group had significantly lower middle and cervical internal adaptation values.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call