Abstract

Differential diagnosis between lymphomas and reactive lymphoid proliferations often requires ancillary techniques and morphologic evaluation. Flow cytometry (FCM) and polymerase chain reaction (PCR) can aid the detection of monoclonal B-cell populations. In the present study, the sensitivity and specificity of these two methods in the study of cytology specimens were compared. Eighty-six cytologic specimens from 81 patients (lymph nodes, solid organs, and body cavities) were evaluated. These specimens were taken from three groups of patients: those who underwent an initial evaluation for suspected lymphoma; those who were previously diagnosed with B-cell lymphoma and were now evaluated for possible disease recurrence; and those who were diagnosed with a nonhematologic malignancy. Histologic diagnosis was available for 51 samples. All samples were tested by FCM for the detection of monoclonality using kappa:lambda ratio and for clonal immunoglobulin heavy chain (IgH) gene rearrangements using a single-round PCR after cytologic evaluation. Tissue morphology, FCM and PCR results, and clinical findings in specimens without histologic diagnosis were correlated. Histologic evaluation (N = 51) revealed 44 specimens with B-cell malignancy. Twenty of the 44 lymphoma specimens (45%) were accurately diagnosed in cytologic smears, 18 (41%) were classified as suspicious of lymphoma, and 6 (14%) were diagnosed as reactive. FCM had superior sensitivity compared with PCR (77% vs. 64%). Fifty-six percent of specimens with B-cell malignancy were FCM+/PCR+, 23% were FCM+/PCR-, 14% were FCM-/PCR+, and 7% were FCM-/PCR-. The combined use of FCM and PCR resulted in a diagnosis of B-cell lymphoma in 41 (93%) of 44 B-cell lymphoma specimens and increased the sensitivity of fine needle aspiration by 48%. Both FCM and PCR aid in the diagnosis of lymphoid lesions in cytology specimens, and both can detect monoclonal B-cell populations that may be interpreted in cytology smears as reactive, even by experienced cytologists. Although FCM had higher sensitivity than PCR test in the present study, their combined use should be considered because of a relatively large number of specimens that were detected as monoclonal only with PCR.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.