Abstract

Introduction: Dosimetry is of crucial importance in radiation processing of food. Among others, plastic film has been widely used for dosimetry in radiation therapy since its density is quite similar to the equivalent biological materials. In this study, the depth dose distribution was estimated by using gafchromic film for the purpose of dosimetry in food irradiation.
 Experimental: The HD-V2 gafchromic dosimetry film was employed to measure the interested dose instead of ion chamber. A stack of 19 PMMA (polymethyl methacrylate) sheets interleaved with 20 pieces of gafchromic film was made. The phantom was applied in the low energy X-ray beams (maximum 100 keV) to obtain the depth dose profile.
 Results: A significant correlation between absorbed doses (D) and color level or optical density (O.D.) of irradiated dosimetry films was observed. The fitting function has the form of , where a, b, c are the parameters to be fitted. The depth dose distribution in the 30 mm thickness phantom was inferred from the calibration.
 Conclusion: The present method and the depth dose profile to be obtained are very meaningful in the processing of foodstuffs by radiation.

Highlights

  • Dosimetry is of crucial importance in radiation processing of food

  • The phantom was applied in the low energy X-ray beams to obtain the depth dose profile

  • As can be seen from the figure, the color of the dosimetry films changed with regard to the irradiation dose

Read more

Summary

Introduction

Dosimetry is of crucial importance in radiation processing of food. Among others, plastic film has been widely used for dosimetry in radiation therapy since its density is quite similar to the equivalent biological materials. The depth dose distribution was estimated by using gafchromic film for the purpose of dosimetry in food irradiation. Radiation processing of food requires the determination of dose distribution in the product package. Radiochromic dosimetry film can be an adapted device, owing to advantages such as being thin, uniform, and flexible, as well as having radiation absorption characteristics corresponding to agricultural products. Such dosimetry film is a solid-state detector which detects the structural properties of crystalline solids as they undergo a change when exposed to radiation. Mehta et al 5, in 1996, intensively determined the depth dose distributions in polymethyl methacrylate (PMMA) and polyethylene (PE) for a 10

Objectives
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have