To compare the load-bearing capacity of three and four-unit fixed partial denture (FPD) with two different designs of pontics reinforced with industrial glass fibers at two different positions of the FPD. A total of 64 samples were made with Bis-acryl composite temporary material and reinforced with industrial glass fibers (E-glass). The specimens were divided into eight groups (groups I-VIII) depending on the number of units, type of pontic design and area of placement of fibers. A universal testing machine was used to evaluate and compare the load-bearing capacity of the specimens. The evaluated data were statistically analyzed using one-way ANOVA and Bonferroni post hoc tests (p ≤ 0.05). Three-unit interim FPD and modified ridge lap pontic design showed greater load-bearing capacity after reinforcement with glass fibers than a four-unit interim FPD and hygienic pontic design, respectively. Fiber placement at the occlusal plus connector area as well as the cervical plus connector area had comparable results. Industrial glass fibers (E-glass) could be used as a cheaper alternative but clinical performance and their safety are yet to be evaluated. Reinforcement with industrial-grade glass fibers can be a cheaper option for increasing the load-bearing capacity of interim partial dentures, but it needs to be studied in vivo through further studies.