Portal hypertension (PH) and esophageal varices (EVs) are a matter of extensive research. According to current Baveno VII guidelines, in patients with compensated advanced chronic liver disease (cACLD), liver stiffness measurement (LSM) < 15 kPa and PLT count > 150 × 109/L, upper endoscopy (UE) is not mandatory, and the emphasis should be set on non-invasive methods for evaluation of clinically significant portal hypertension (CSPH). The aim of this study is to establish whether liver stiffness (LS) measured by 2D-SWE could be used as a predictor for the presence and severity of EVs in cirrhotic patients. In total, 86 patients of whom 32 with compensated liver cirrhosis (cLC) and 54 with decompensated liver cirrhosis (dLC) were examined in the Gastroenterology clinic of University hospital "Kaspela", Plovdiv, Bulgaria. Each patient underwent LS assessment by 2D-SWE and EVs grading by UE. EVs were detected in 47 (54.7%) patients, 23 (49%) of them were stage 4-high-risk EVs (HREV). The cut-off value for LS that differentiates HREV from the rest was set at 2.49 m/s with 100% sensitivity and 100% specificity (AUC 1.000, CI 0.925). Conclusions: 2D-SWE can be used as a non-invasive method in the assessment of only high-grade esophageal varices. For the other grades, upper endoscopy remains the method of choice.