Abstract

Background Diastolic left ventricular (LV) function is commonly characterized by transmitral flow pattern in human beings. Recently, Doppler tissue imaging (DTI) was introduced to evaluate diastolic function. The aim of our study was to validate DTI in the evaluation of diastolic function in mice. Methods We measured indices of diastolic function using pulsed DTI, and transmitral Doppler and LV pressure and its maximal rate of decrease (LVdP/dt min), before and 4 weeks after aortic banding in C57BL/6 mice. Results Peak early diastolic velocity and ratio of peak early-to-late filling velocities, both measured by DTI, were significantly reduced after banding, thereby indicating diastolic dysfunction. Diastolic dysfunction was confirmed by impaired LV dP/dt min, decreased transmitral early filling velocity, and transmitral early-to-late filling velocity ratio using transmitral Doppler. Conclusion DTI detects diastolic dysfunction caused by chronic pressure overload in mice after aortic banding. DTI is suggested to be implemented as part of routine mouse echocardiography for evaluation of LV diastolic function.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.