Abstract

AbstractSpecimens of Type 304 austenitic stainless steel with carbon contents of 0.017, 0.024, 0.046, and 0.059% were subjected to intergranular corrosion tests in acidified copper sulfate solutions with and without additions of metallic copper. In the annealed condition the steels were not attacked by either of the test environments. After a sensitizing heat treatment, both test procedures showed essentially the same behavior; intergranular corrosion occurred only on steels with 0.046 and 0.059% carbon.Of the visual, metallographic, and scanning electron microscope methods of examining test specimens, the latter produces a superior permanent record. Tactile examination proved to be a simple method of determining intergranular attack on specimens bent after exposure to the test solutions. Evaluation of the examination methods led to a proposed sequence for examining specimens, from a low-sensitivity visual examination to a high-sensitivity examination with a scanning electron microscope. Limitations of the test methods are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.