Abstract

High-rise residential developments are rapidly increasing in urban areas. Smaller residential units in this high rise bring a reduction in windows, resulting in poor indoor air ventilation. In addition, materials used in interiors can emit volatile organic compounds (VOCs), which can significantly affect human health. Since people spend 90% of their time indoors, an evaluation of indoor air quality is especially important for high-rise residential buildings with an analysis of determining factors. This study aims to measure the concentrations of VOCs, formaldehyde, and particulate matter (PM2.5 and PM10) in 9 high-rise residential buildings in Bangkok by using the accidental sampling method (n = 252) and to investigate possible important determining factors. The results show that the average concentrations of VOCs, formaldehyde, PM2.5, and PM10 in 9 high-rise residential buildings were at good to moderate levels in the indoor air quality index (IAQI) and that high pollutant concentrations were rarely found except in new constructions. Moreover, it was found that the age of buildings shows strong correlations with all pollutants (p value < 0.0001). Old buildings showed significantly lower pollutant concentrations than new and under-construction buildings at a 95% confidence level. The findings from this investigation can be used as part of sustainable well-being design guidelines for future high-rise residential developments.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call