Abstract

Stress relaxation of tensile type specimens under fast neutron irradiation at 288 °C has been studied for 316L stainless steel (SS) in the Japan Materials Testing Reactor. In-pile stress-relaxation tests were carried out at fast neutron fluence levels of 1.3×10 24, 5.5×10 24 and 1.5×10 25 n/m 2 ( E>1 MeV). These tests were carried out at the applied total strain levels of 0.06%, 0.1%, 0.3% and 0.75%. In order to evaluate the thermal stress-relaxation behavior and to distinguish it from the irradiation induced stress-relaxation behavior, out-of-pile stress-relaxation tests were also performed at 288 °C in air using an electric furnace. This paper describes results of in-pile and out-of-pile stress-relaxation tests on 316L SS tensile specimens. These results are compared with the literature data by Foster et al. [J. Nucl. Mater. 252 (1998) 89] which were mainly obtained from bend beam specimens. Moreover, these experimental results are compared with analytical results obtained using Nagakawa's model [J. Nucl. Mater. 212–215 (1994) 541].

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.