Abstract

Background: Assessment of tissue oxygenation is an important aspect of detection and monitoring of patients with peripheral artery disease (PAD). Hyperspectral imaging (HSI) is a non-contact technology for assessing microcirculatory function by quantifying tissue oxygen saturation (StO2). This study investigated whether HSI can be used to monitor skin oxygenation in patients with PAD after appropriate treatment of the lower extremities. Methods: For this purpose, 37 patients with PAD were studied by means of ankle–brachial index (ABI) and HSI before and after surgical or endovascular therapy. Thereby, the oxygenation parameter StO2 and near infrared (NIR) perfusion index were quantified in seven angiosomes on the diseased lower leg and foot. In addition, the effects of skin temperature and physical activity on StO2 and the NIR perfusion index and the respective inter-operator variability of these parameters were investigated in 25 healthy volunteers. Results: In all patients, the ABI significantly increased after surgical and endovascular therapy. In parallel, HSI revealed significant changes in both StO2 and NIR perfusion index in almost all studied angiosomes depending on the performed treatment. The increase in tissue oxygenation saturation was especially pronounced after surgical treatment. Neither heat nor cold, nor physical activity, nor repeated assessments of HSI parameters by independent investigators significantly affected the results on StO2 and the NIR perfusion index. Conclusions: Tissue oxygen saturation data obtained with HSI are robust to external confounders, such as temperature and physical activity, and do not show inter-operator variability; therefore, can be used as an additional technique to established methods, such as the ABI, to monitor peripheral perfusion in patients with PAD.

Highlights

  • Peripheral artery disease (PAD) is a common vascular disease that affects more than 200 million people worldwide [1,2,3]

  • Six seconds were required for the acquisition of each hyperspectral data cube

  • We studied whether Hyperspectral imaging (HSI) is feasible for detecting changes in tissue oxygenation saturation after surgical or endovascular therapy in patients with peripheral artery disease (PAD)

Read more

Summary

Introduction

Peripheral artery disease (PAD) is a common vascular disease that affects more than 200 million people worldwide [1,2,3]. Methods: For this purpose, 37 patients with PAD were studied by means of ankle–brachial index (ABI) and HSI before and after surgical or endovascular therapy. The effects of skin temperature and physical activity on StO2 and the NIR perfusion index and the respective inter-operator variability of these parameters were investigated in 25 healthy volunteers. Nor physical activity, nor repeated assessments of HSI parameters by independent investigators significantly affected the results on StO2 and the NIR perfusion index. Conclusions: Tissue oxygen saturation data obtained with HSI are robust to external confounders, such as temperature and physical activity, and do not show inter-operator variability; can be used as an additional technique to established methods, such as the ABI, to monitor peripheral perfusion in patients with PAD

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call