Abstract

The source of groundwater seepage problem being experienced by some engineering buildings in a part of southwestern Nigeria was investigated by carrying out comparative study of the hydraulic conductivity (K) of the soil types underlying the area using integrated approaches involving geotechnical and geophysical methods.Soil samples were collected from six different towns on which standard geotechnical tests including natural moisture content, grain size distribution, linear shrinkage, specific gravity, liquid and plastic limits, compaction, triaxial and K test were carried out. Also, geophysical data were acquired at seventy-two locations using Schlumberger array with a current electrode spacing of 40m. The resistivity data obtained were subsequently inverted to obtain the subsurface 2D hydraulic conductivity section.The results obtained imply that the soil types investigated is semi-pervious with K values ranging from 1.06 x 10-5 to 5.71 x10-5cm/s. These values suggest moderate groundwater flow which might account for the seepage that was observed. Four lithologies (lateritic topsoil, clayey-sand, sandy-clay and fractured/weathered bedrock) were delineated. The geotechnical analysis result suggests the soil investigated could be classified as poorly graded sandy-clay and/or silty-clay. This soil exhibit plasticity index ranging from 12.72 to 19.75%, with specific gravity ranging from 2.47 to 2.73; the maximum dry density (MDD) varies from 1699.5 kg/cm3 to 1915kg/cm3 and the optimum moisture content (OMC) ranges from 12.05% to 16.32%.The result of the t-test results performed implied that at 95% t–confidence level, there is a good correlation between the results obtained from both approaches employed.

Highlights

  • Lateritic clay has been found to be one of the most abundant soils in the tropical part of the world

  • The source of groundwater seepage problem being experienced by some engineering buildings in a part of southwestern Nigeria was investigated by carrying out comparative study of the hydraulic conductivity (K) of the soil types underlying the area using integrated approaches involving geotechnical and geophysical methods

  • DeGroot et al (2012) showed that this large range in values has resulted in the development of numerous field methods that cater to the soil type being tested and the anticipated hydraulic conductivity

Read more

Summary

Introduction

Lateritic clay has been found to be one of the most abundant soils in the tropical part of the world. The hydraulic conductivity (K) of soils is a key parameter that is required for analysis and design of numerous civil engineering works such as seepage, groundwater development, consolidation, drainage, contaminant studies. DeGroot et al (2012) showed that this large range in values has resulted in the development of numerous field methods that cater to the soil type being tested and the anticipated hydraulic conductivity. Geotechnical parameters such as permeability of rocks and soils are required for subsurface characterization. It is commonly determined from geotechnical approach such as pump tests, grain size analysis, which involves drilling or digging in order to obtain samples; which over a large area are cumbersome, time-consuming and expensive

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.