Abstract
The University of Texas at Arlington (UTA) has performed experiments in which high power 3Ah LiNixCoyAl1-x-yO2 batteries have been studied at high C rates. The first of three identical cells has been discharged using a 10 kHz (50% duty cycle), high C rate (100C/300 A) pulsed discharge procedure and a 1C constant current (CC) - constant voltage (CV) recharge procedure. The second cell has been discharged using a 1C CC procedure and recharged using a 111 mHz (33% duty cycle), high C rate (33C/100 A) pulsed recharge procedure. The third cell, the control cell, has been cycled using a 1C CC discharge procedure and 1C CC-CV recharge procedure. The results of these experiments enable the impact each respective high rate procedure has on cell aging to be better understood. The experimental procedures and methods will be discussed in detail and the results of the experiments will be presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.