Abstract

Prior research identified possible interstitial pulmonary fluid, concerning for early high altitude pulmonary edema (HAPE), in a large percentage of trekkers above 3000 m using a comprehensive 28-view pulmonary ultrasound protocol. These trekkers had no clinical symptoms of HAPE despite these ultrasound findings. The more common 4-view lung ultrasound protocol (LUP) is accurate in rapidly detecting interstitial edema during resource-rich care. The objective of this study was to evaluate whether the 4-view LUP detects interstitial fluid in trekkers ascending to Everest Base Camp. Serial 4-view LUP was performed on 15 healthy trekkers during a 9-d ascent from Kathmandu to Everest Base Camp. Ascent protocols complied with Wilderness Medical Society guidelines for staged ascent. A 4-view LUP was performed in accordance with the published 2012 international consensus protocols on lung ultrasound. Symptom assessment and 4-view LUP were obtained at 6 waypoints along the staged ascent. A 4-view LUP was positive for interstitial edema if ≥3 B-lines were detected in 2 ultrasound windows. A single participant had evidence of interstitial lung fluid at 5380 m as defined by the 4-view LUP. There was no evidence of interstitial fluid in any participant below 5380 m. One participant was evacuated for acute altitude sickness at 4000 m but showed no preceding sonographic evidence of interstitial fluid. In this small study, sonographic detection of interstitial fluid, suggestive of early HAPE, was not identified by the 4-view LUP protocol.