Abstract

Thermal and structural responses of divertor target were evaluated by using finite element method. High heat flux simulating ELMs at the level of 100MW/m2 was assumed onto the tungsten armor, and surface temperature profile was obtained. When dynamic heat load over 100MW/m2 was applied, the maximum surface temperature exceeded 1300°C, and it caused recrystallization of tungsten regardless of the heat transfer below it. The result was used to conduct dynamic heat load experiment on tungsten, and material behavior of tungsten was evaluated under dynamic heat load. This study also proposed new concept of divertor heat sink which can distribute high heat flux and transfers the heat to high temperature medium. It consists of tungsten armor, composite enhanced with high thermal conductivity fiber, and heat transport system applying phase transition. High heat flux simulating ELMs was also applied to target surface of the divertor, temperature gradient, thermal stress of tungsten and composite were evaluated. Based on the results of analysis, thermal structural requirement was considered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.